System3d - optymalne rozwiązania dla obróbki skrawaniem

Sonda dotykowa TS 460 z połączeniem bezprzewodowym to nowej generacji kompaktowa sonda przeznaczona do obrabiarek z automatyczną zmianą narzędzi. Elektryczny interfejs pozwala na bezpośrednie podłączenie do większości systemów CNC włącznie z FANUC.

TS460.jpg

 

  Cable Radio and infrared
Workpiece touch probe TS 248 / TS 260 TS 460
Probe accuracy ≤ ± 5 µm when using a standard T404 stylus

Probe repeatability
Repeated probing from one direction

2 σ ≤ 1 µm at a probing velocity of 1 m/min 
Typical values: 
2 σ ≤ 1 µm at a probing velocity of 3 m/min 
2 σ ≤ 4 µm at a probing velocity of 5 m/min

Deflection of probe contact ≤ 5 mm in all directions (with stylus length L = 40 mm)
Deflection force

Axial: approx. 8 N (TS 248: approx. 4 N)
Radial: approx. 1 N (TS 248: approx. 0.5 N)

Probing velocity ≤ 5 m/min
Collision protection* Optional
Protection EN 60 529 IP67
Operating temperature 10 °C to 40 °C
Storage temperature –20 °C to 70 °C
Mass without taper shank Approx. 0.15 kg Approx. 0.2 kg
Fastening*

With taper shank1) (only with radial flange socket)
By M28 x 0.75 external thread
By coupling joint with M22 x 1 external thread

With taper shank1)
By M12 x 0.5 external thread

Electrical connection* M12 flange socket, 8-pin; axial or radial
Cable length ≤ 25 m
Voltage supply 15 V to 30 V DC / ≤ 100 mA (with no load) 2 batteries (rechargeable or non-rechargeable) 
1/2 AA or size LR2, each 1 V to 4 V
Operating time Continuous duty: typically 400 h2) with lithium batteries
Output signals
  • Trigger signals S and S (square-wave signal and its inverted signal)
  • Floating trigger output
HTL signal levels

UH ≥ 20 V at –IH ≤ 20 mA 
UL ≤ 2.8 V at IL ≤ 20 mA 
at 24 V DC rated voltage

Signal transmission Cable Radio and infrared transmission (selectable) with 360° range to SE
Transmitter/receiver unit*
  • SE 660 for radio and infrared transmission3)
  • SE 642 for infrared transmission3)
  • SE 540 for infrared transmission; for integration in the spindle head
TS switch-on/off Radio or infrared signal (selectable) from SE

* Please select when ordering
1) See overview, page 18
2) Reduced operating time if there is much surrounding radio traffic, or short but frequent probing intervals
3) Common SE for TS 460 and TT 460

pobierz katalog pdf

All information from  www.heidenhain.com