System3d - optymalne rozwiązania dla obróbki skrawaniem

TS 220 to sonda z połączeniem kablowym zaprojektowana dla obrabiarek z ręczną wymianą narzędzi.

TS220.jpg

Specifications
TS 220
TS 230
Probe accuracy
≤ ± 5 µm when using a standard stylus
Probe repeatability
Repeated probing from one direction
2 σ ≤ 1 µm at a probing velocity of 1 m/min
Typical values:
2 σ ≤ 1 µm at a probing velocity of 3 m/min 
2 σ ≤ 4 µm at a probing velocity of 5 m/min
Deflection of probe contact
≤ 5 mm in all directions (with stylus length L = 40 mm)
Deflection force
Axial approx. 8 N, radial approx. 1 N
Probe velocity
≤ 5 m/min
Protection EN 60529
IP 55
Operating temperature
Storage temperature
10 °C to 40 °C
–20 °C to 70 °C
Weight
Approx. 0.7 kg without taper shank
Taper shank*
  • With taper shank (for selection see Touch Probes brochure)
  • Without taper shank (connecting thread M30 x 0.5)
Power supply
5 V ±5% / ≤ 100 mA (with no load)
10 to 30 V / ≤ 100 mA (with no load)
Output signals
One square-wave signal and its inverted signal
Trigger signals S and S
Signal levels
TTL 
UH ≥2.5 V at –IH ≤ 20 mA
UL ≤ 0.5 V at IL ≤ 20 mA 
at 5 V rated voltage
HTL
UH ≥20 V at –IH ≤ 20 mA
UL ≤ 2.8 V at IL ≤ 20 mA 
at 24 V rated voltage
Electrical connection
Spiral cable, 1.5 m 
with 6-pin quick disconnect
Spiral cable, 1.5 m 
with 7-pin M23 male connector
Cable length
≤ 50 m

* Please select when ordering

pobierz katalog pdf

All information from  www.heidenhain.com