Tool monitoring with a TL Laser System is a very flexible solution.The contact-free optical measurement enables you to check even the smallest tools rapidly, reliably, and without collision.Even the most sensitive tools are completely safe from damage.

Tool monitoring occurs at the rated shaft speed in the real clamping system, and as such under real operating conditions.Errors on the tool, spindle and holder can immediately be detected and corrected.

TL Laser Systems

The laser systems are available in different versions for various maximum tool diameters.The units have an integral blowing unit to remove chips and coolant from the tool with a blast of compressed air.

The CNC uses measuring cycles to process the output signal of the laser systems and carries out the necessary calculations.Measuring cycles for the TNC426/430 and iTNC530 controls are included with the TL laser systems.

TL_nano.jpg

Specifications
TL Nano
TL Micro 150
TL Micro 200
TL Micro 300
Tool diameter 
Central measurement
Tangential measurement from above
Tangential measurement from the side

0.03 to 37 mm
0.03 to 44 mm
0.03 to 44 mm

0.03 to 30 mm
0.03 to 30 mm
0.03 to 30 mm

0.1 to 80 mm
0.1 to 98 mm
0.1 to 122 mm

0.1 to 180 mm
0.1 to 324 mm
0.1 to 428 mm
Repeatability
± 0.2 µm
± 1 µm
Spindle speed*
For individual tooth measurement, optimized to standard spindles or HSC spindles (> 30 000 min-1)
Laser
Wavelength / Power
Protection class IEC 825
Visible red-light laser with beam focused at center of system
630 to 700 nm / < 1 mW 
2
Input signals
Square-wave signals 24 V – 
  • ENABLE 0 transmission enabling
  • ENABLE 1 receiver enabling 1 
  • ENABLE 2 receiver enabling 2
Output signals
Square-wave signals 24 V – 
  • DYN dynamic triggering signal 
  • STA static triggering signal 
  • LASER OK
Power supply
24 V / 160 mA
Electrical connection
M23 flange socket, male, 12-pin
Cable outlet*
On the side
On the side or bottom
Mounting
Within the machine work envelope
Protection EN 60 529
IP 68 (when connected, with sealing air)
Tool cleaning
Integral blowing unit
Operating temperature
Storage temperature
10 to 40 °C 
0 to 50 °C
Weight
Incl. blowing unit
Cable outlet on side
Approx. 0.70 kg
Approx. 0.85 kg
Approx. 0.95 kg
Approx. 1.15 kg
Cable outlet on bottom
-
Approx. 0.90 kg
Approx. 1.00 kg
Approx. 1.20 kg

* Please select when ordering